HOME
     Overview
     Structure
     Culture
     Working
     EI & Toroidal
     R & Toroidal
     CD & Toroidal
CERTIFICATES
AND HONORS
SALES NETWORK
SPEECH
COMMENTS
CONTACT US
VIDEO
To Export Director
General Enquiry
 
"HENGNIU", a Good Electronic Transformer Brand from the
Hometown of the World Famous Great Panda.
Comparison on CE and Toroidal Transformer Electronic Data
HDZJ¼ì-16
Type
CD Transformer
Toroidal Transformer
Volume
40VA
40VA
Model
CD
HDB-40
Intensity of Reactance
Primary to Secondary/Ground
3.5KV/2.0mA
3.5KV/2.0mA
No-load
No-load Current£¨mA£©
220V/50Hz
6.0
6.9
 
 
 
No-load Loss£¨W£©
0.3
0.6
No-load Voltage£¨V£©
0-1.17-12.72-14.99-17.2-20.77
0-1.05-12.86-14.83-16.82-18.78
Load
Load Current£¨A£©
£².£±
£².£±
Load Voltage£¨V£©
£°£­£°.£¹£¸£­£±£±.£±£­£±£³£­£±£´.£¸£³£­£±£·.£¸£¶
£°£­£°.£¹£¶£­£±£±.£¸£µ£­£±£³.£¶£¸£­£±£µ.£´£µ£­£±£·.£²£¸
Voltage Regulation£¨%£©
£±£´£¥£¨£°£­£±£¸£Ö£©
£¸.£°£¥£¨£°£­£±£¸£Ö£©
DC Resistance£¨¦¸£©
Primary 1£¨¦¸£©220V
£·£·.£°
£´£¶.£°
Secondary£¨¦¸£©28V
£°.£¶£³
£°.£³£¸
Temperature-rise
£´£°.£±
£²£°.£¹
Test Record
CD
 
To:   £²£¹.£±¡æ
T1:   30.1¡æ
     CH1
COLD: 70.26
HOL;  88.11
¦¤T:   40.1
TIME:  2.12.18
Toroidal
 
To:    30.5¡æ
T1:    30.7¡æ
      CH1
COLD: 45.98
HOL;  49.62
¦¤T:   20.9
TIME:  2.14.25
Circuit£º
Remark:
1. The temperature-rise of HDB-40 lower 19.2¡æ than its R counterpart.
2. The comprehensive data of HDB-40 better than its R counterpart.
 
 
OEM, ODM, Customer-designed Drawing,Sample & Specification Acceptable. Copyright 1997