HOME
     Overview
     Structure
     Culture
     Working
     EI & Toroidal
     R & Toroidal
     CD & Toroidal
CERTIFICATES
AND HONORS
SALES NETWORK
SPEECH
COMMENTS
CONTACT US
VIDEO
To Export Director
General Enquiry
 
"HENGNIU", a Good Electronic Transformer Brand from the
Hometown of the World Famous Great Panda.
Comparison on R and Toroidal Transformer Electronic Data -
HDZJ¼ì-16
Type
R Transformer
Toroidal Transformer
Volume
15VA
15VA
Model
R10
HDB-15
Intensity of Reactance
Primary to Secondary/Ground
3.5KV/1mA
3.5KV/1mA
No-load
No-load Current£¨mA£©
220V/50Hz
2.0
2.0
 
 
 
No-load Loss£¨W£©
0.2
0.2
No-load Voltage£¨V£©
28.26
28.26
Load
Load Current£¨A£©
0.5
0.5
Load Voltage£¨V£©
24.63
25.57
Voltage Regulation£¨%£©
12.84%
9.52%
DC Resistance£¨¦¸£©
Primary 1£¨¦¸£©220V
202.0
139.0
Secondary£¨¦¸£©28V
4.0
3.2
Temperature-rise
27.3
18.0
Test Record
R
 
To:   27.7¡æ
T1:   27.6¡æ
      CH1
COLD: 202.0
HOL;  222.8
¦¤T:   27.3
TIME:  2.50.51
Toroidal
 
To:    28.6¡æ
T1:    27.9¡æ
       CH1
COLD: 139.3
HOL;  148.4
¦¤T:   18.0
TIME:  2.52.18
Circuit£º
Remark:
1. The temperature-rise of HDB-15 lower 9.3¡æ than its R counterpart.
2. The comprehensive data of HDB-15 better than its R counterpart.
 
 
OEM, ODM, Customer-designed Drawing,Sample & Specification Acceptable. Copyright 1997